dellemc.openmanage.ome_smart_fabric_info module – Retrieves the information of smart fabrics inventoried by OpenManage Enterprise Modular

Note

This module is part of the dellemc.openmanage collection (version 8.5.0).

To install it, use: ansible-galaxy collection install dellemc.openmanage. You need further requirements to be able to use this module, see Requirements for details.

To use it in a playbook, specify: dellemc.openmanage.ome_smart_fabric_info.

New in dellemc.openmanage 7.1.0

Synopsis

  • This module retrieves the list of smart fabrics in the inventory of OpenManage Enterprise Modular.

Requirements

The below requirements are needed on the host that executes this module.

  • python >= 3.9.6

Parameters

Parameter

Comments

ca_path

path

added in dellemc.openmanage 5.0.0

The Privacy Enhanced Mail (PEM) file that contains a CA certificate to be used for the validation.

fabric_id

string

Unique Id of the fabric.

fabric_id is mutually exclusive with fabric_name.

fabric_name

string

Name of the fabric.

fabric_name is mutually exclusive with fabric_id.

hostname

string / required

OpenManage Enterprise Modular IP address or hostname.

password

string / required

OpenManage Enterprise Modular password.

port

integer

OpenManage Enterprise Modular HTTPS port.

Default: 443

timeout

integer

added in dellemc.openmanage 5.0.0

The socket level timeout in seconds.

Default: 30

username

string / required

OpenManage Enterprise Modular username.

validate_certs

boolean

added in dellemc.openmanage 5.0.0

If false, the SSL certificates will not be validated.

Configure false only on personally controlled sites where self-signed certificates are used.

Prior to collection version 5.0.0, the validate_certs is false by default.

Choices:

  • false

  • true ← (default)

Notes

Note

  • Run this module from a system that has direct access to Dell OpenManage Enterprise Modular.

  • This module supports check_mode.

Examples

---
- name: Retrieve details of all smart fabrics
  dellemc.openmanage.ome_smart_fabric_info:
    hostname: "192.168.0.1"
    username: "username"
    password: "password"
    ca_path: "/path/to/ca_cert.pem"

- name: Retrieve details of a specific smart fabric identified by its fabric ID
  dellemc.openmanage.ome_smart_fabric_info:
    hostname: "192.168.0.1"
    username: "username"
    password: "password"
    ca_path: "/path/to/ca_cert.pem"
    fabric_id: "61c20a59-9ed5-4ae5-b850-5e5acf42d2f2"

- name: Retrieve details of a specific smart fabric identified by its fabric name
  dellemc.openmanage.ome_smart_fabric_info:
    hostname: "192.168.0.1"
    username: "username"
    password: "password"
    ca_path: "/path/to/ca_cert.pem"
    fabric_name: "f1"

Return Values

Common return values are documented here, the following are the fields unique to this module:

Key

Description

error_info

dictionary

Details of the HTTP Error.

Returned: on HTTP error

Sample: {"error": {"@Message.ExtendedInfo": [{"Message": "Unable to complete the request because the resource URI does not exist or is not implemented.", "MessageArgs": [], "MessageId": "CGEN1006", "RelatedProperties": [], "Resolution": "Check the request resource URI. Refer to the OpenManage Enterprise-Modular User's Guide for more information about resource URI and its properties.", "Severity": "Critical"}], "code": "Base.1.0.GeneralError", "message": "A general error has occurred. See ExtendedInfo for more information."}}

msg

string

Status of smart fabric information retrieval.

Returned: always

Sample: "Successfully retrieved the smart fabric information."

smart_fabric_info

list / elements=string

Returns the information about smart fabric.

Returned: success

Sample: [{"Description": "Fabric f1", "FabricDesign": [{"Actions": {"#NetworkService.GetApplicableNodes": {"target": "/api/NetworkService/Fabrics('61c20a59-9ed5-4ae5-b850-5e5acf42d2f2')/FabricDesign/NetworkService.GetApplicableNodes"}, "Oem": {}}, "FabricDesignNode": [{"ChassisName": "Chassis-X", "NodeName": "Switch-B", "Slot": "Slot-A2", "Type": "WeaverSwitch"}, {"ChassisName": "Chassis-X", "NodeName": "Switch-A", "Slot": "Slot-A1", "Type": "WeaverSwitch"}], "Name": "2xMX9116n_Fabric_Switching_Engines_in_same_chassis", "NetworkLink": [{"DestinationInterface": "ethernet1/1/38", "DestinationNode": "Switch-B", "SourceInterface": "ethernet1/1/38", "SourceNode": "Switch-A"}, {"DestinationInterface": "ethernet1/1/37", "DestinationNode": "Switch-B", "SourceInterface": "ethernet1/1/37", "SourceNode": "Switch-A"}, {"DestinationInterface": "ethernet1/1/39", "DestinationNode": "Switch-B", "SourceInterface": "ethernet1/1/39", "SourceNode": "Switch-A"}, {"DestinationInterface": "ethernet1/1/40", "DestinationNode": "Switch-B", "SourceInterface": "ethernet1/1/40", "SourceNode": "Switch-A"}]}], "FabricDesignMapping": [{"DesignNode": "Switch-A", "PhysicalNode": "NODEID1"}, {"DesignNode": "Switch-B", "PhysicalNode": "NODEID2"}], "Health": {"Issues": [{"Category": "Audit", "DetailedDescription": "The SmartFabric is not healthy because the interface for an uplink mentioned in the message is not in operational status.", "Message": "The SmartFabric is not healthy because the interface JRWSV43:ethernet1/1/35 for uplink 1ad54420-b145-49a1-9779-21a579ef6f2d is not in operational status.", "MessageArgs": [], "MessageId": "NFAB0016", "Resolution": "Make sure that all the uplink interfaces are in operational status.", "Severity": "Warning", "TimeStamp": "2019-09-25T11:50:06Z"}, {"Category": "Audit", "DetailedDescription": "The SmartFabric is not healthy because one or more VLTi links are not connected.", "Message": "The SmartFabric is not healthy because all InterSwitch Links are not connected.", "MessageArgs": [], "MessageId": "NFAB0017", "Resolution": "Make sure that the VLTi cables for all ISLs are connected and operational as per the selected fabric design.", "Severity": "Warning", "TimeStamp": "2019-09-25T11:50:06Z"}, {"Category": "Audit", "DetailedDescription": "The SmartFabric is not healthy because the interface for an uplink mentioned in the message is not in operational status.", "Message": "The SmartFabric is not healthy because the interface 6H7J6Z2:ethernet1/1/35 for uplink 1ad54420-b145-49a1-9779-21a579ef6f2d is not in operational status.", "MessageArgs": [], "MessageId": "NFAB0016", "Resolution": "Make sure that all the uplink interfaces are in operational status.", "Severity": "Warning", "TimeStamp": "2019-09-25T11:50:06Z"}, {"Category": "Audit", "DetailedDescription": "The SmartFabric is not healthy because one or more of the uplink interfaces are not bonded.", "Message": "The SmartFabric is not healthy because the uplink 1ad54420-b145-49a1-9779-21a579ef6f2d interface 6H7J6Z2:ethernet1/1/35 is not bonded to the other interfaces in the uplink.", "MessageArgs": [], "MessageId": "NFAB0019", "Resolution": "Make sure that the Link Aggregation Control Protocol (LACP) is enabled on all ports on the remote switch to which the uplink ports from the fabric are connected.", "Severity": "Warning", "TimeStamp": "2019-09-25T11:50:06Z"}, {"Category": "Audit", "DetailedDescription": "The SmartFabric is not healthy because one or more of the uplink interfaces are not bonded.", "Message": "The SmartFabric is not healthy because the uplink 1ad54420-b145-49a1-9779-21a579ef6f2d interface JRWSV43:ethernet1/1/35 is not bonded to the other interfaces in the uplink.", "MessageArgs": [], "MessageId": "NFAB0019", "Resolution": "Make sure that the Link Aggregation Control Protocol (LACP) is enabled on all ports on the remote switch to which the uplink ports from the fabric are connected.", "Severity": "Warning", "TimeStamp": "2019-09-25T11:50:06Z"}], "Status": "4000"}, "Id": "61c20a59-9ed5-4ae5-b850-5e5acf42d2f2", "LifeCycleStatus": [{"Activity": "Create", "Status": "2060"}], "Multicast": [{"FloodRestrict": true, "IgmpVersion": "3", "MldVersion": "2"}], "Name": "f1", "OverrideLLDPConfiguration": "Disabled", "ScaleVLANProfile": "Enabled", "Servers": [{"ChassisServiceTag": "6H5S6Z2", "ConnectionState": true, "ConnectionStateReason": 101, "DeviceCapabilities": [1, 2, 3, 4, 7, 8, 9, 41, 10, 11, 12, 13, 14, 15, 208, 16, 17, 18, 212, 30, 31], "DeviceManagement": [{"DnsName": "iDRAC-6GZK6Z2", "InstrumentationName": "", "MacAddress": "4c:d9:8f:7a:7c:43", "ManagementId": 135185, "ManagementProfile": [{"AgentName": "iDRAC", "HasCreds": 0, "ManagementId": 135185, "ManagementProfileId": 135185, "ManagementURL": "https://[2607:f2b1:f081:9:4ed9:8fff:fe7a:7c43]:443/", "ProfileId": "WSMAN_OOB", "Status": 1000, "StatusDateTime": "2019-10-29 09:30:38.552", "Version": "3.20.21.20"}], "ManagementType": 2, "NetworkAddress": "100.96.24.28"}, {"DnsName": "iDRAC-6GZK6Z2", "InstrumentationName": "", "MacAddress": "4c:d9:8f:7a:7c:43", "ManagementId": 135186, "ManagementProfile": [{"AgentName": "iDRAC", "HasCreds": 0, "ManagementId": 135186, "ManagementProfileId": 135186, "ManagementURL": "https://[2607:f2b1:f081:9:4ed9:8fff:fe7a:7c43]:443/", "ProfileId": "WSMAN_OOB", "Status": 1000, "StatusDateTime": "2019-10-29 09:30:38.552", "Version": "3.20.21.20"}], "ManagementType": 2, "NetworkAddress": "[2607:f2b1:f081:9:4ed9:8fff:fe7a:7c43]"}], "DeviceName": "MX-6H5S6Z2:Sled-1", "DeviceServiceTag": "6GZK6Z2", "Enabled": true, "Id": 10071, "Identifier": "6GZK6Z2", "LastInventoryTime": "2019-10-29 09:30:38.552", "LastStatusTime": "2019-10-29 09:41:51.051", "ManagedState": 3000, "Model": "PowerEdge MX840c", "PowerState": 17, "SlotConfiguration": {"ChassisId": "10072", "ChassisName": "MX-6H5S6Z2", "ChassisServiceTag": "6H5S6Z2", "DeviceType": "1000", "SledBlockPowerOn": "None blocking", "SlotId": "10084", "SlotName": "Sled-1", "SlotNumber": "1", "SlotType": "2000"}, "Status": 1000, "SystemId": 1894, "Type": 1000}], "Summary": {"NodeCount": 2, "ServerCount": 1, "UplinkCount": 1}, "Switches": [{"ChassisServiceTag": "6H5S6Z2", "ConnectionState": true, "ConnectionStateReason": 101, "DeviceCapabilities": [1, 2, 3, 5, 7, 8, 9, 207, 18, 602, 603, 604, 605, 606, 607, 608, 609, 610, 611, 612, 613, 614, 615, 616, 617, 618, 619, 620, 621, 622], "DeviceManagement": [{"DnsName": "", "InstrumentationName": "MX9116n Fabric Engine", "MacAddress": "20:04:0F:4F:4E:04", "ManagementId": 135181, "ManagementProfile": [{"HasCreds": 0, "ManagementId": 135181, "ManagementProfileId": 135181, "ManagementURL": "", "ProfileId": "", "Status": 1000, "StatusDateTime": "2019-10-29 09:30:36.273"}], "ManagementType": 2, "NetworkAddress": "100.96.24.36"}, {"DnsName": "", "InstrumentationName": "MX9116n Fabric Engine", "MacAddress": "20:04:0F:4F:4E:04", "ManagementId": 135182, "ManagementProfile": [{"HasCreds": 0, "ManagementId": 135182, "ManagementProfileId": 135182, "ManagementURL": "", "ProfileId": "", "Status": 1000, "StatusDateTime": "2019-10-29 09:30:36.273"}], "ManagementType": 2, "NetworkAddress": ""}], "DeviceName": "MX-6H5S6Z2:IOM-A2", "DeviceServiceTag": "6H7J6Z2", "Enabled": true, "Id": 10074, "Identifier": "6H7J6Z2", "LastInventoryTime": "2019-10-29 09:30:36.332", "LastStatusTime": "2019-10-29 09:31:00.931", "ManagedState": 3000, "Model": "MX9116n Fabric Engine", "PowerState": 17, "SlotConfiguration": {"ChassisId": "10072", "ChassisName": "MX-6H5S6Z2", "ChassisServiceTag": "6H5S6Z2", "DeviceType": "4000", "SledBlockPowerOn": "null", "SlotId": "10079", "SlotName": "IOM-A2", "SlotNumber": "2", "SlotType": "4000"}, "Status": 1000, "SystemId": 2031, "Type": 4000}, {"ChassisServiceTag": "6H5S6Z2", "ConnectionState": true, "ConnectionStateReason": 101, "DeviceCapabilities": [1, 2, 3, 5, 7, 8, 9, 207, 18, 602, 603, 604, 605, 606, 607, 608, 609, 610, 611, 612, 613, 614, 615, 616, 617, 618, 619, 620, 621, 622], "DeviceManagement": [{"DnsName": "", "InstrumentationName": "MX9116n Fabric Engine", "MacAddress": "E8:B5:D0:52:61:46", "ManagementId": 135183, "ManagementProfile": [{"HasCreds": 0, "ManagementId": 135183, "ManagementProfileId": 135183, "ManagementURL": "", "ProfileId": "", "Status": 1000, "StatusDateTime": "2019-10-29 09:30:37.115"}], "ManagementType": 2, "NetworkAddress": "100.96.24.37"}, {"DnsName": "", "InstrumentationName": "MX9116n Fabric Engine", "MacAddress": "E8:B5:D0:52:61:46", "ManagementId": 135184, "ManagementProfile": [{"HasCreds": 0, "ManagementId": 135184, "ManagementProfileId": 135184, "ManagementURL": "", "ProfileId": "", "Status": 1000, "StatusDateTime": "2019-10-29 09:30:37.115"}], "ManagementType": 2, "NetworkAddress": ""}], "DeviceName": "MX-6H5S6Z2:IOM-A1", "DeviceServiceTag": "JRWSV43", "Enabled": true, "Id": 20881, "Identifier": "JRWSV43", "LastInventoryTime": "2019-10-29 09:30:37.172", "LastStatusTime": "2019-10-29 09:31:00.244", "ManagedState": 3000, "Model": "MX9116n Fabric Engine", "PowerState": 17, "SlotConfiguration": {"ChassisId": "10072", "ChassisName": "MX-6H5S6Z2", "ChassisServiceTag": "6H5S6Z2", "DeviceType": "4000", "SledBlockPowerOn": "null", "SlotId": "10078", "SlotName": "IOM-A1", "SlotNumber": "1", "SlotType": "4000"}, "Status": 1000, "SystemId": 2031, "Type": 4000}], "Uplinks": [{"Id": "1ad54420-b145-49a1-9779-21a579ef6f2d", "MediaType": "Ethernet", "Name": "u1", "NativeVLAN": 1, "Summary": {"NetworkCount": 1, "PortCount": 2}, "UfdEnable": "Disabled"}]}]

Authors

  • Kritika Bhateja(@Kritka-Bhateja)